Find matching DEF, DPF, EGR, and AdBlue warnings
View prices and available package options
Plug-in programming with no tools or laptop required
Stage 1 tuning, DPF Delete, and additional features
Step-by-step ordering process
Worldwide shipping information
Available payment options
Multi-vehicle pricing and upgrade options
Answers before and after purchase
What to choose, how it works and features
Installation, usage and troubleshooting
Technical articles and guides
DPF error
AdBlue error
DEF error
EGR error





A dashboard warning can tell you when to add fluid or when the system needs further checks. The 2012 Sprinter DEF system uses diesel exhaust fluid in the selective catalytic reduction (SCR) system, part of the van’s emissions control equipment. DEF goes into its own tank, separate from the fuel tank. If Sprinter guides show different tank filler locations, use the markings and the owner’s manual for your van to find the correct opening. Look for the DEF label in the filler area before pouring fluid into the van’s separate filler. Fill the DEF tank with ready-to-use fluid that meets the specific requirements in the owner’s manual. DEF is a mixture of urea and water. Never substitute plain water for DEF.
A low DEF warning on a Sprinter van calls for a level check and a DEF refill if needed. If the DEF tank level rises after a refill and the warning persists, read the whole message for any indication of an SCR fault. A recurring DEF warning alone cannot confirm a fault in the tank level sender or heater. It also cannot confirm a fault in DEF pumps. Depending on the van’s configuration, low fluid or a system fault can trigger a countdown toward a starting restriction. A refill may clear a low-level warning once the van recognizes the added fluid. An underlying SCR fault can keep the warning active.
DEF can freeze in the tank in cold weather. The Sprinter DEF heater helps thaw the fluid. A fault in the tank heater element can interfere with thawing, so confirm the cause before you replace the heater. If the van’s displayed DEF level stays low after a refill, a tank level sensor fault is one possibility. The reading alone cannot establish sensor failure.
NOx sensors monitor nitrogen oxides in the exhaust and help the van assess SCR operation. The check engine light is a general warning. Use the accompanying fault information to narrow down whether the warning involves the heater, a sensor or another part of the SCR system.
OBDtune is a handheld plug-in tool for supported Mercedes-Benz diesel vehicles. A supported SCR script can suppress related dashboard warnings without removing or replacing components. The DEF counter reset option can temporarily reset a supported countdown while SCR continues to operate. A failed part still needs repair, and safe operation requires a separate assessment.
| Situation | What to look for |
|---|---|
| Sprinter DEF filler identification | Use the marking to identify the DEF tank opening, and use the fluid specified for the Sprinter van. The DEF label helps you avoid pouring the fluid into the fuel tank. |
| Sprinter DEF level rises after a refill | A rising DEF tank level suggests the Sprinter registered the DEF refill. Read the full warning if the Sprinter still shows an SCR fault or a starting restriction after it registers the added fluid. |
| Sprinter DEF level stays low after a refill | The Sprinter may need time to register the added fluid in the DEF tank. A persistently low DEF tank level reading can also point to a level measurement problem. |
| Sprinter DEF level falls again after a refill | The Sprinter van can show a gradual drop in tank level as it uses fluid. Compare tank level readings over time if the van displays the low-level message again soon after you add fluid to the Sprinter van. |
| Sprinter DEF heater warning in cold weather | A heater fault on the Sprinter van can delay thawing of the fluid in the van’s DEF tank. The fault details can help distinguish a heater circuit problem from a level measurement issue on the Sprinter van. |
| Sprinter NOx or SCR warning with DEF in the tank | The van can display a normal DEF tank level while reporting an SCR fault. A DEF tank level reading cannot establish fluid quality or show whether the DEF delivery system is working properly. Use the fault details to narrow down which component or circuit needs checking. |
| Sprinter DEF counter reset | A temporary reset can change a supported countdown. If the DEF warning returns, compare the van’s full message with the one you recorded before the reset. |
SCR total delete – no longer necessary to repair the SCR system and refill the AdBlue fluid
Removes Check Engine error
Removes 0 Remaining Starts error
Removes Starts idle error
Removes Check AdBlue error
Ability to roll back to factory settings
Maintains the dealer warranty
Easy pass emissions test ability
We suggest deleting all of the following components together (SCR, EGR, Flaps and DPF) as all of these elements work together as one system
Disables SCR (DEF) system on equipped vehicles
Disables Swirl Flaps in the intake manifold
Optionally disables Diesel Particulate Filter
Disables EGR valve
Ability to roll back to factory settings
Maintains the dealer warranty
Easy pass emissions test ability
Temporary solution – start the engine and drive to workshop without limitations but the SCR still needs to be repaired
Ability to reset engine starts
counter as many times as needed
SCR system continues to work
Absolutely legal
Maintains the dealer warranty